Ceska verze

Afilmywap Prem Ratan Dhan Payo Better -

     Welding inverter is an alternative to a conventional welding transformer. Modern semiconductors allow to replace the traditional mains transformer with a switching power supply, which is much lighter, smaller and allows easy current adjustment via a potentiometer. The advantege is also that the output current is DC. DC current is less dangerous than AC and prevents arc extinction.

     For this inverter i chose topology, which is the most common in welding inverters - forward converter with two switches. In my article about switchning supplies it is a topology II.D. Input mains voltage passes through an EMI filter and is smoothed with high capacity capacitors. Since the inrush current of those capacitors would be too high, there's a softstart circuit. After switching ON, the primary smoothing capacitors are charging via resistors, which are later bypassed by the contact of a relay. As power switches, IGBT transistors IRG4PC40W are used. They are driven through a forward gate-drive transformer TR2 and shaping circuits with BC327 PNP transistors. The control integrated circuit is UC3844. It's similar to UC3842, but it has its pulse-width limited to 50%. Working frequency is 42kHz. Control circuit is powered by an auxiliary power supply of 17V. Current feedback, due to high currents, is using a current transformer Tr3. Voltage drop accros the sensing resistor 4R7/2W is approximately proportional to the output current. Output current can be controlled by potentiometer P1, which determines the threshold of the current feedback. Threshold voltage of the pin 3 of UC3844 (current sensing) is 1V.

     Power semiconductors require cooling. Most of the heat is dissipated in output diodes. Upper diode, consisting of 2x DSEI60-06A, must in worst case handle the average current of 50A and the dissipation of 80W (total of both diodes). Lower diode STTH200L06TV1 (doube diode package with both internal diodes connected in parallel) must in worst case handle an average current of 100A and the dissipation of nearly 120W. Maximum total dissipation of the secondary rectifier is 140W. The heatsink must be able to handle it. To the thermal resistance you must include the junction-case Rth, case-sink Rth and sink-ambient Rth. DSEI60-06A diodes don't have insulation pads and the cathode is connected to the the heatsink. Output choke L1 is therefore in the negative rail. It is advantageous because in this configuration, there's no high-frequency voltage on the heatsink. You can use another type of diodes, for example a parallel combination of a sufficient number of the most accessible diodes, such as MUR1560 or FES16JT. Note that the maximum average current of the lower diode is twice the current of the upper diode. Calculation of the power dissipation of the IGBTs is more complicated because in addition to conductive losses there are also switching losses. Loss of each transistor is up to about 50W. It is also necessary to cool the reset diodes UG5JT and the mains bridge rectifier. The power dissipation of the reset diodes depends on the construction of Tr1 (inductance, stray inductance), but is much lower than the dissipation of the IGBTs. The rectifier bridge has a power dissipation of up to about 30W. UG5JT diodes and the rectifying bridge are placed on the same heatsink as the IGBTs. UG5JT diodes also can be replaced with MUR1560 or FES16JT or other ultrafast diodes. During construction it is also necessary to decide the maximum loading factor of the welding inverter, and accordingly select size of heatsinks, winding gauges and so on. It is also good to add a fan.

     Switching transformer Tr1 is wound on two ferrite EE cores, each with a central column cross section 16x20mm. The total cross section is therefore 16x40mm, the core must have no air gap. 20 turns primary winding is wound using 14 wires of a 0.5 mm diamater. It would be better to use 20 wires, but they didn't fit into my core. Secondary winding has 6 turns of a copper strip (36 x 0.5 mm). Forward gate-drive transformer Tr2 is made with an emphasis on low stray inductance. It is trifillary wound, using three twisted insulated wires of 0.3 mm diameter, and all the windings have 14 turns. Core is made of material H22, middle column has a diameter of 16mm, with no gaps. Current sensing transformer Tr3 is made from an EMI suppression choke on a toroidal core. The original winding with 75 turns of 0.4 mm wire works as a secondary. Primary has just 1 turn. Polarity of all the transformer windings must be kept (see dots in schematic)! L1 inductor has a ferrite EE core, middle column has cross section 16x20mm. It has 11 turns of a copper strip (36 x 0.5mm) and the total air gap in the magnetic circuit is 10mm. Its inductance is cca 12uH.

     The auxiliary 17V switching power supply, including Tr4, is described in more detail here. The simplest welding inverter on Pic 1 has no voltage feedback. Voltage feedback does not affect the welding, but affects the power consumption and heat losses in the idle state. Without the output voltage feedback there is quite high output voltage (approximately 100V) and the PWM controller ia running at its max duty cycle, thereby increasing the power consumption and heating of components. Therefore, it is better to implement the voltage feedback. You can inspire on Pic 2. The feedback can be connected directly because the controll circuit is isolated from mains. The reference voltage is 2.5V. Select the R2 to set the open circuit voltage. You can find useful info in datasheet of UC3842, 3843, 3844, 3845 or in its another datasheet. Inspiration for modifications you can also find in 3-60V 40A supply.

     Interesting links from which I drew:
http://svarbazar.cz/phprs/index.php?akce=souvis&tagid=3
http://leo.wsinf.edu.pl/~leszek/spawarki/
http://www.y-u-r.narod.ru/Svark/svark.htm
http://www.emil.matei.ro/weldinv3.php
http://nexor.electrik.org/svarka/barmaley/kosoy/shema.gif and a little modified: http://nexor.electrik.org/svarka/barmaley/kosoy1/shema.gif

Afilmywap Prem Ratan Dhan Payo Better -

In conclusion, while both "Prem Ratan Dhan Payo" and Afilmywap have their pros and cons, it's essential to prioritize legal and safe options when accessing movies and TV shows. So, if you're in the mood for a romantic drama, "Prem Ratan Dhan Payo" might be worth watching, but make sure to access it through a legitimate platform!

In the era of digital entertainment, accessing movies and TV shows has become easier than ever. Platforms like Afilmywap offer a vast library of content, including Bollywood films, at the click of a button. On the other hand, we have movies like "Prem Ratan Dhan Payo", a romantic drama starring Salman Khan and Sonakshi Sinha, which was released in 2015. afilmywap prem ratan dhan payo better

So, which one is better: "Prem Ratan Dhan Payo" or Afilmywap? Well, it ultimately depends on what you're looking for. If you're in the mood for a romantic drama with a talented cast, "Prem Ratan Dhan Payo" might be the way to go. However, if you're looking for a platform that offers a vast library of content at your fingertips, Afilmywap might be an attractive option. In conclusion, while both "Prem Ratan Dhan Payo"

But, it's crucial to consider the legal and ethical implications of using platforms like Afilmywap. While they may offer a wide range of content, they often operate in a gray area, and using them may not be the most legal or safe option. Platforms like Afilmywap offer a vast library of

"Prem Ratan Dhan Payo" is a romantic drama film directed by Vinil Mathew. The movie tells the story of Prem (Salman Khan), a young man who falls in love with a woman named Pooja (Sonakshi Sinha). However, their love is threatened when Prem's past comes back to haunt him. The film received mixed reviews from critics but performed moderately well at the box office.

If you're looking for a legal and safe way to access movies like "Prem Ratan Dhan Payo", you might want to consider streaming platforms like Amazon Prime Video, Netflix, or Hotstar. These platforms offer a wide range of content, including Bollywood films, and operate within the bounds of the law.

Afilmywap, on the other hand, is a popular online platform that offers a vast collection of movies, TV shows, and music. The website allows users to download or stream their favorite content for free. While it may seem like an attractive option for those looking to access a wide range of content without breaking the bank, it's essential to consider the pros and cons of using such platforms.


Homemade inverter welder (welding inverter) schematic
Pic 1 - Homemade inverter welder (welding inverter) schematic - click to enlarge.

voltage feedback
Pic 2 - Voltage feedback addition.

 Tr1 Secondary made of a copper strip
Tr1 Secondary made of a copper strip

 Tr1 Secondary made of a copper strip
Secondary winding with a transformer paper insulation on top. Then I added an insulation tape (about 10 layers) for an extra insulation.

Secondary and a half of a core
Secondary with a half of the core

Tr1 with wound primary
Tr1 with wound primary. Note that the primary doesn't go to the edges, so it can't cut to the secondary.

switching transformer Tr1 with core
switching transformer Tr1 with core

Old Czechoslovak switching supply from the mainframe
Old Czechoslovak switching supply from the mainframe (5V 50A DBP 236 Kosire ZPA). From two such supplies I salvaged parts for the construction of the inverter (ferrites, heatsinks, distance posts, spools, inductors, copper strips, ...)

Diodes STTH200L06TV1 and DSEI60-06A on the heatsink
Diodes STTH200L06TV1 and DSEI60-06A ultrafast diodes on the heatsink

heatsink with diodes, TR1, L1, copper tape
heatsink with diodes, TR1, L1 and copper strip

Gate drive transformer TR2 with trifillar winding (GDT)
Gate-drive transformer (GDT) TR2 with a trifillar winding

Tests of the exciter UC3844, TR2 and shaping circuit
Tests of the exciter UC3844, TR2 and shaping circuit

Shaping circuit for gates
Shaping circuit for gates

afilmywap prem ratan dhan payo better


Ready to first start :).
Ready to first start :).

Short-term test for 150A - all survived:).
Short-term test for 150A - all survived:).

IGBT, bridge, reset diodes, forming circuits, GDT TR2 and the UC3844 driver.
IGBT, bridge, reset diodes, forming circuits, GDT TR2 and the UC3844 driver.

Current transformer TR3
Current transformer TR3

It is welding :)
It is welding :)

Measurement of arc voltage - long arc
Measurement of arc voltage - long arc

Measurement of arc voltage - short arc
Measurement of arc voltage - short arc

afilmywap prem ratan dhan payo better


afilmywap prem ratan dhan payo better
Inverter with auxiliary supply in a temporary case.



The first test (the short-circuit current).


The second test, half the mains voltage, output voltage is too low to hold the arc. At the end you can se PWM on an oscilloscope.


Third test - it is allready welding.


Welding and safety at work - how it should never look like:).



home